ADD |
There is less than six pounds of refrigerant in the tank. Add refrigerant to the tank. See "Adding Refrigerant to the Tank." |
| |
|
CAL |
The scale is out of calibration. Calibrate the scale. |
| |
|
CH-F |
The unit has recovered 300 pounds of refrigerant. Press SHIFT/RESET and FILTER at the same time, then replace the filter-drier.
|
| |
|
CH-P |
The vehicle's A/C system has less than 25psi. Do not
attempt recovery if the A/C system has no refrigerant. Check for restrictions at access fittings. Check to be sure that manifold valves are open. To continue, press HOLD/CONT. |
| |
|
CL-L |
The low side clearing routine is in progress. This occurs when you press RECOVER and can last up to four minutes. |
| |
|
CLR |
The unit is in the self-clearing process. |
| |
|
CON |
The vacuum pump will run continuously. Press HOLD/CONT to stop. |
| |
|
CPL |
The specified cycle function (recovery, evacuation, charging or adding refrigerant) is complete. |
| |
|
FIL |
The filter-drier changeout is in progress. |
| |
|
FULL |
The refrigerant recovery tank is full. Replace the tank. |
| |
|
HI-P |
The discharge pressure is above 435 psi. Check to be sure the unit tank's red valve is open. |
| |
|
OIL |
The vacuum pump has run for 10 hours. While the OIL message is displayed, press SHIFT/RESET and ENTER at the same time to reset the
timer. Then change the vacuum pump oil. |
| |
|
SCAL |
The scale is damaged, disconnected, out of calibration or overloaded (it cannot exceed 80 pounds or 36.3 kilograms). Calibrate the
scale |
| |
|
U-HI |
There is positive pressure on the vacuum pump. Press SHIFT/RESET and then RECOVER to remove the pressure, than continue the evacuation
procedure. |
| |
|
99LB |
The maximum amount displayed during recovery is 99 pounds. Press SHIFT/RESET to clear the display. |