17700a and 34700

Choose from the following issues to view the related trouble shooting tips.

1. Compressor does not start or stops prematurely

2. Runs a short time, but does not complete recovery

3. Runs but won't shut off

4. No power when Main Power switch is on - no display showing

5. Audible tone sounds during refrigerant transfer

6. Refrigerant does not flow

7. Vacuum pump runs, but low side gauge does not register an appropriate vacuum

8. Error/Message Codes

RECOVERY OPERATION

1. Compressor does not start or stops prematurely

 

Power cord not plugged in or no power at plug

 

Check circuit for power

   

 

MAIN POWER switch is off

 

Turn of switch

   

 

FULL message on digital display

 

Change tanks. See Installing the Tank.

   

 

HI-P message on digital display

 

Be sure tank valves are open and hoses are properly connected to the tank or check the scale calibration. See CHECKING THE SCALE ACCURACY.

   

 

CH-F message on digital display

 

Remove and replace the filter-drier. See REPLACING THE FILTER-DRIER and be sure to pull a vacuum

   

 

Faulty components

 

Call service center

2. Runs a short time, but does not complete recovery

 

Tank valves closed

 

Open both valves and be sure hoses are properly connected to the tank

   

 

Manifold valves closed

 

Open both valves

   

 

Faulty components

 

Call service center

3. Runs but won't shut off

 

Oil drain valve open

 

Close the valves

   

 

Leak in vehicle system

 

Locate and repair all system leaks

   

 

Hoses are not properly connected to the vehicle

 

Check hose connections

   

 

Faulty components

 

Call service center

RECHARGING OPERATION

4. No power when Main Power switch is on - no display showing

 

Unit unplugged

 

Plug the unit into a power source

   

 

No power at wall outlet

 

Locate the problem with the outlet or change outlets.

5. Audible tone sounds during the refrigerant transfer

 

Tansfer stopped or too slow

 

Start the A/C system and pull the remaining refrigerant into system. See RECHARGING THE A/C SYSTEM or be sure the blue hose has access to the tank

   

 

Refrigerant supply empty

 

Add refrigerant to the tank

   

 

Blue LIQUID tank valve closed

 

Open the blue LIQUID tank valve

6. Refrigerant does not flow

 

Refrigerant supply empty

 

Add refrigerant to the tank

   

 

Flow restriction

 

Check all connections on the A/C system (the 17700A/17001A should have adapters on both the low and high side fittings and the couplers on the 34700/34701 should be open), or Check the blue hose connection at the tank's blue valve - be sure it is getting access, or Check the tank's valve - it should be open, or Be sure the A/C system has had a minimum of 15 minutes of vacuum

7. Vacuum pump runs, but low side gauge does not register an appropriate vacuum

 

Pump oil contaminated

 

Flush and change the vacuum pump oil

   

 

Charging line loose

 

Check connections

   

 

Manifold leaking

 

Check connections

   

 

Low side valve closed

 

Open low side valve

   

 

3/8" hose improperly connected to pump

 

Check connections

8. ERROR/MESSAGE CODE

ADD

There is less than six pounds of refrigerant in the tank. Add refrigerant to the tank. See "Adding Refrigerant to the Tank."

   

CAL

The scale is out of calibration. Calibrate the scale.

   

CH-F

The unit has recovered 300 pounds of refrigerant. Press SHIFT/RESET and FILTER at the same time, then replace the filter-drier.

   

CH-P

The vehicle's A/C system has less than 25psi. Do not attempt recovery if the A/C system has no refrigerant. Check for restrictions at access fittings. Check to be sure that manifold valves are open. To continue, press HOLD/CONT.

   

CL-L

The low side clearing routine is in progress. This occurs when you press RECOVER and can last up to four minutes.

   

CLR

The unit is in the self-clearing process.

   

CON

The vacuum pump will run continuously. Press HOLD/CONT to stop.

   

CPL

The specified cycle function (recovery, evacuation, charging or adding refrigerant) is complete.

   

FIL

The filter-drier changeout is in progress.

   

FULL

The refrigerant recovery tank is full. Replace the tank.

   

HI-P

The discharge pressure is above 435 psi. Check to be sure the unit tank's red valve is open.

   

OIL

The vacuum pump has run for 10 hours. While the OIL message is displayed, press SHIFT/RESET and ENTER at the same time to reset the timer. Then change the vacuum pump oil.

   

SCAL

The scale is damaged, disconnected, out of calibration or overloaded (it cannot exceed 80 pounds or 36.3 kilograms). Calibrate the scale

   

U-HI

There is positive pressure on the vacuum pump. Press SHIFT/RESET and then RECOVER to remove the pressure, than continue the evacuation procedure.

   

99LB

The maximum amount displayed during recovery is 99 pounds. Press SHIFT/RESET to clear the display.