Choose from the following issues to view the related trouble shooting tips.

1. Compressor light illuminates but compressor does not start

2. Compressor light does not illuminate and compressor does not start

3. Compressor runs but does not move refrigerant

4. During recovery unit shuts off on high pressure

5. Unit will not pull down to appropriate vacuum level

1. Compressor light illuminates but compressor does not start

 

Compressor head pressure is too high

 

Turn Valve 1 to the EQUALIZE position for a couple of seconds before starting

   

 

Compressor thermal protector has tripped

 

Allow compressor to re-cool before starting

2. Compressor light does not illuminate and compressor does not start

 

TANK FULL light is on

 

Attach the float cable to the float connector on the tank or replace the full tank with an empty tank

   

 

HIGH PRESSURE light is on

 

The high side pressure switch has tripped; turn Valve 1 to EQUALIZE for a couple of seconds to reduce the high side pressure

   

 

COMPRESSOR switch is not on

 

Press the COMPRESSOR switch to ON

3. Compressor runs but does not move refrigerant

 

Valve 2 is not in the RECOVER position

 

Turn Valve 2 to RECOVER

   

 

The RECOVER light for Valve 2 is not illuminated

 

Toggle the Valve 2 switch to illuminate the RECOVER light

   

 

The ball valves on the hoses are not open

 

Open the ball valves

   

 

Valve 1 is in the EQUALIZE position

 

Turn Valve 1 to NORMAL

4. During recovery unit shuts off on high pressure

 

The refillable tank valves are not open

 

Open the tank valves

   

 

Valve 2 is not in the RECOVER position

 

Turn Valve 2 to RECOVER

5. Unit will not pull down to appropriate vacuum level

 

There is a leak in the A/C system

 

Fix the leak

   

 

Valve 1 is in the EQUALIZE position

 

Turn Valve 1 to normal