34134a

Choose from the following issues to view the related trouble shooting tips.

1. Compressor does not start or stops prematurely.

2. Runs but gauges won't indicate 13 in Hg (0.44 Bar)

1. Compressor does not start or stops prematurely

 

No power

 

Check for power at plug or outlet

   

 

**OVERLOAD** is displayed

 

Move refrigerant from unit tank to approved refrigerant storage tank. See RECHARGING A/C SYSTEM.

   

 

HIGH PRESSURE is displayed

 

Be sure tank valves are open and hoses are properly connected to the unit tank.

   

 

**SCALE** is displayed

 

The scale is damaged, disconnected, out of calibration or overloaded.

2. Runs but gauges won't indicate 13 in Hg (0.44 Bar)

 

Oil drain valve open.

 

Close the oil drain valve.

   

 

Leak in vehicle system.

 

Locate and repair all system leaks.

   

 

Manifold valves not open.

 

Open valves.